English
Español
Svenska
Deutsch
Français
Polski
Italia
中国人
AIR DATA
Supply
Exhaust
Air flow
Nm
3
/h
CFM
kg/h
kg/s
l/min
l/s
m
3
/h
m
3
/s
Nl/min
Nm
3
/h
Nm
3
/s
SCFM
Temperature
°C
°C
°F
Relative humidity
%
Supply
Exhaust
Inlet air pressure (abs)
Pa
Pa
mmH
2
O
inH
2
O
psi
Differential pressure
Pa
Pa
mmH
2
O
inH
2
O
psi
PRODUCT DATA
-
MODEL E
Rotor diameter
mm
Well height
mm
1.6
1.8
2
Rotor depth
mm
Rotational speed
rpm
Matrix material
Aluminium (Condensation)
Epoxy (Condensation)
Hybrid with silica gel (Enthalpy)
Hybrid with molecular sieve (Enthalpy)
Silica gel (Adsorption)
Molecular sieve (Adsorption)
Exchanger orientation
Vertical
Horizontal
Hub
Ball bearing with shaft
Ball bearing with shaft, corrosion resistant
Plane of intersection
Vertical plane of intersection
Horizontal plane of intersection
Purge sector
None
Front side on the right
Front side on the left
Back side on the right
Back side on the left
Delivered on the side for later assembly at any position
Purge sector
None
Front side top
Front side bottom
Back side top
Back side bottom
Delivered on the side for later assembly at any position
Drive equipment
None
Constant drive 3x380-420V
Constant drive 3x220-240V
IBC VariMax step drive without Modbus
IBC VariMax NG step drive with Modbus
OJ DRHX + MRHX step drive with Modbus
Rotation detector
None
Rotation detector
Drive location
None
Floor right side
Floor left side
Floor right side, control unit not attached to casing
Floor left side, control unit not attached to casing
Drive belt
Round belt
Power belt
Seal
Brush seal
Special brush seal
<a href="https://www.heatex.com/knowledge/technical-dictionary/?cat_name=Terminology&que_slug=special-brush-seal" target='_blank'> <span style="margin-left:5px"> Read more</span></a>.</span>
Casing Options
Casing type
Standard
Covered
Non-standard dimensions
Height
mm
Width
mm
Corrosion protected framework
Inspection hatches
Cable glands
Condensate tray, drain on motorside
Condensate tray, drain on non-motorside
For hygienic certified casing, contact Heatex
Select another model
Calculate performance
PERFORMANCE RESULTS
Supply
Exhaust
Supply
Exhaust
Air flow (in/out)
Nm³/h
Air flow (in/out)
Nm
3
/h
CFM
kg/h
kg/s
l/min
l/s
m
3
/h
m
3
/s
Nl/min
Nm
3
/h
Nm
3
/s
SCFM
Pressure drop
1
Pa
Pa
mmH
2
O
inH
2
O
psi
Temp./ humidity/ enthalpy efficiency
%
Temp./ humidity/ enthalpy effectiveness
%
Temperature before/after
°C
°C
°F
Temperature (wet bulb) before/after
°C
°C
°F
Relative humidity before/after
%
Absolute humidity before/after
6
g/kg
Air velocity (face/channel)
m/s
Inlet air pressure (abs)
Pa
Pa
mmH
2
O
inH
2
O
psi
Differential pressure
Pa
Pa
mmH
2
O
inH
2
O
psi
Transferred power
kW
Condensate
l/h
EATR / OACF
%/-
Energy efficiency/class
5
%
Erp efficiency
%
NOTES AND WARNINGS
1
Actual pressure drop/pressure drop corrected to density 1.2 kg/m3 or 0.075 lb/ft3
5
Calculated without motor power consumption
6
Humidity/ dry air
SUMMARY
Price
Net
Gross
Heat exchanger product code
EUR
Total price
%
Discount
Dimensions (WxHxd)
mm
Total weight
kg
0
Customer
Include return of investment calculation
Return on Investment Calculation
Export to PDF
Return on Investment Calculation
×
×
Total hours must be less than 8760
Total hours must be a maximum 24
Total days must be a maximum 7
Total weeks must be a maximum 52.14
Geographical location
11
Ahmedabad, India
Alexandria, Egypt
Athens, Greece
Auckland, New Zeeland
Bangaluru, India
Bangkok, Thailand
Beijing, China
Belgrade, Serbia
Berlin, Germany
Brasilia, Brazil
Bratislava, Slovakia
Bucharest, Romania
Budapest, Hungary
Calgary, Canada
Canberra, Australia
Cape Town, South Africa
Chengdu, China
Chennai, India
Chicago, USA
Christchurch, New Zeeland
Columbus, USA
Goa, India
Guangzhou, China
Hanoi, Vietnam
Ho Chi Minh, Vietnam
Hong Kong, China
Houston, USA
Hyderabad, India
Incheon, South Korea
Jakarta, Indonesia
Kolkata, India
Kuala Lumpur, Malaysia
Ljubljana, Slovenia
London, UK
Malmo, Sweden
Manila, Philippines
Melbourne, Australia
Mexico city, Mexico
Minneapolis, USA
Montreal, Canada
Mumbai, India
Nairobi, Kenya
New Delhi, India
New York, USA
Osaka, Japan
Paris, France
Perth, Australia
Phoenix, USA
Portland, USA
Prague, Czech Republic
Pune, India
Quebec, Canada
RIGA, Latvia
Rome, Italy
Sao Paulo, Brazil
Select a location
Seoul, South Korea
Shanghai, China
Singapore, Republic of Singapore
Sofia, Bulgaria
Sydney, Australia
Taipei, Taiwan
Tallinn, Estonia
Tokyo, Japan
Toronto, Canada
Vancouver, Canada
Vilnius, Lithuania
Warsaw, Poland
Yangon, Myanmar
Zagreb, Croatia
Service hours
hrs / day
Service days
days / week
Service weeks
weeks / year
Total yearly service hours
Heat exchanger price
EUR
Energy cost heating
EUR/kWh
EUR/kWh
EUR/BTU
Energy saving heating
EUR
Energy cost cooling
EUR/kWh
EUR/kWh
EUR/BTU
Energy saving cooling
EUR
Calculate ROI
Total yearly energy reduction
kWh
kWh
BTU
Yearly CO
2
reduction
9
kg
kWh
BTU
Yearly savings
EUR
Payback period
Months
10
Installed Heating/Cooling Power
Energy Usage
Without heat exchanger
With heat exchanger
Installed power reduction
Without heat exchanger
With heat exchanger
Energy saving
Heating coil max power
(kW)
Heating coil
(kWh)
Cooling coil max power
(kW)
Cooling coil
(kWh)
Energy Demand
Break-Even
Energy Demand
Customer
×
×
Sorry, an error occurred while processing your request.
Customer
Objectline1
Objectline2
Mollier
×
Error
Supply
Exhaust
Inlet air pressure (abs)
Pa
Temperature
°C
Relative humidity
%
Vapor Pressure
Pa
Humidity/ Dry air
kg/kg
Moisture Wet Air
kg/kg
Wet bulb temp.
°C
Entalphi dry air
kJ/kg
Cond. temp.
°C
Density
kg/m
3
Adiabatic moisture
kg/kg
Inlet air pressure (abs)
×
Elevation (above sea level)
Atmospheric pressure
Elevation (above sea level)
m
m
ft
Inlet air pressure (abs)
Pa